STUDY I
CONDUCTION & THE SURFACE ECG
Shock or no shock?
Compare the electrical signal with the heart’s mechanical response.
Liquid levels show volume, not air inside the chambers.
The relaxed ventricles fill through the open atrioventricular valves.
Two normal beats, then VF. A successful outcome is scripted for this exercise; an organised ECG alone does not prove circulation.
Lead II: frontal view · V1 / V6: chest views
Before activation
The myocardium is at rest. Follow the impulse from the sinoatrial node.
Explore how cardiac electrical activity shapes the surface ECG.
Reading this model
This is a schematic normal beat with an 800 ms cycle, equivalent to 75 beats per minute before slow motion and the end pause. P onset: 20 ms. QRS: 160–250 ms. PR: 140 ms. T wave: 310–520 ms. QT: 360 ms (Bazett QTc approximately 402 ms at 75 bpm). The waveform, activation, mechanical events and controls share the same timeline. Mechanical phase boundaries are illustrative and vary with heart rate, loading and conduction. In this example the AV valves close at 170 ms; ejection runs from 220 to 500 ms; ventricular filling resumes at 560 ms. Repolarisation and the end of ejection overlap.
The traces illustrate representative Lead II, V1 and V6 shapes. The Lead II marker indicates its positive viewing direction towards the left leg, along the frontal-plane axis from the right arm; V1 and V6 are chest-lead views. The positive T wave in V1 is one normal variant; V1 can also have a normally inverted T wave. Small terminal deflections vary.
The arrow illustrates the dominant activation direction. Its direction and size are schematic, not a measured mean QRS axis or a calculated projection for all three leads. Regional activation and recovery are simplified. The ECG is an illustrative waveform, not a calculated body-surface signal from this drawing. The heart is tilted towards the patient’s left. This schematic anatomical tilt is not a measurement of the mean QRS electrical axis. The lead markers stay referenced to the patient: Lead II is a frontal-plane view, while V1 and V6 are chest-lead views from a different plane. They are shown together for comparison. Electrode symbols show viewpoints, not placement.
Grid cells represent 40 ms horizontally and 0.1 mV vertically. The display is scaled to fit, so cells may be rectangular. Slow motion changes playback speed only.
The bright blue and red liquid levels illustrate changing blood volume. The dark blue and red areas above the level are part of the volume illustration, not air or empty space in the heart. Actual chambers remain blood-filled, with volume changing as their walls move. Blue is the conventional diagram colour for right-heart blood; actual venous blood is dark red. Purple, amber and teal describe the surrounding muscle. Blood remains within every chamber throughout the cycle. Cavity size illustrates changing volume; no numerical ejection fraction or flow rate is implied. Venous return continues while the ventricles eject. The paired right and left valve events are grouped for clarity; anatomical routes and chamber motion are simplified.
Mechanical-cycle basis: OpenStax, Anatomy and Physiology 2e, §19.3; Klabunde, Cardiac Cycle, phases 1–7 (phase pages revised 2023; accessed 9 October 2026). Foundational physiology; the animation timings are modelling choices.
Physiology references: OpenStax: heart orientation · CV Physiology: ECG · University of Utah: lead viewpoints · University of Utah: normal ECG · Ventricular activation and electrical vectors
Continue with ECG interpretation.
Explore conduction and practise assessing patients with different tachyarrhythmias in the ECG course.
Explore the ECG courseFree exercise · no registration · unlimited replay
Source scope and review record
Adult educational model. Treatment decisions follow the cited UK adult guidance; physiology and supporting trial evidence are separate. This exercise is not a standalone clinical protocol.
[FLAG: MISSING — Formal external clinical sign-off and the controlling extraction specification were not available for verification during this website integration.]